Windposts

WIN3 windpost

WIN3 section windposts are designed within the cavity and eliminate the need for cutting blockwork. The posts are suitable for low to medium wind loads where the windpost can fit inside the cavity.

Contact us
1 of 2

Applications and features

Applications:

  • Masonry walls where blockwork is left interrupted.
  • Masonry walls from 2.5m to 6.0m in height.
  • Low to medium wind load areas.

Features:

  • The thickness of C-section windposts varies depending on the load they are required to support and the height of the opening they are installed in.
  • The width and depth of C-section windposts can vary depending on the height of the opening they are supporting.

Product variants

Product variants
DimensionsInsulation parameters
Profile sizeL1 [mm]
Embedded length
M [mm]
Metric thread
D [mm]
Diameter through foam
x [mm]
Depth
y [mm]
Width
t [mm]
Thickness
L [mm]
Length
c [mm] Rd [mm]
Diameter
B [mm]
Box width
Available colourW [mm]
Width
Thermal conductivity [Wm°K]Max lateral load [kN]
WIN3-55-60-455604
WIN3-55-60-555605
WIN3-65-60-465604
WIN3-65-60-565605
WIN3-75-60-475604
WIN3-75-60-575605
WIN3-85-60-485604
WIN3-85-60-585605
WIN3-95-60-595605
WIN3-105-60-5105605
WIN3-115-60-5115605
WIN3-115-60-6115606
WIN3-115-65-8115658

Specification

TypeDepth (x)Width (y)Thickness (t)Height
WIN355/65/75/85/95/105/11560/654/5/6/83000

Type-x-y-t-height

Examples:

  • WIN3-55-60-4-3000
    C-type windpost 55 depth, 60 wide, and 4 mm thick. 3.0m in height supplied with slots for brick ties at 225mm centres.



Materials

ComponentMaterialDescription
PostS355, 1.4301 (304), 1.4401 (316)Carbon steel and stainless steel

Can’t find what you’re looking for?