Concrete balconies

TKQ Thermokorb®

Our TKQ Thermokorb® in collaboration with AVI sets the standard for thermal break solutions. Frequent areas of application are supported balcony slabs and access balconies, recessed balcony connections, platforms, etc.

Contact us
TKQ Thermokorb 3D model
TKQ Thermokorb® real render with three ribs and version with and without insulation
1 of 2

Applications and features

Applications:

  • Supported concrete-to-concrete balconies.
  • Access concrete-to-concrete balconies.
  • Recess concrete-to-concrete balconies.

Features:

  • Fire resistance class R60 - also available in fire resistance class REI 120.
  • Detailed planning literature - technical information, certificates, approvals, and Installation instructions.
  • In case of high shear forces per unit of length, up to ten Thermokorb® TKQ ribs can be arranged side-by-side per metre.
  • Good thermal insulation - 80 mm - insulation thickness and compression module (EPS-W 30 according to standard ÖNORM EN 13163)
  • Can be combined with the Thermokorb® types TKM, TKA, and TDE.

Product variants

The TKQ series is suitable for transferring shear forces for use with supported balconies and recessed balconies.

Each module can have one to three ribs, with 30kN shear load capacity per rib.


Installation cases with Thermokorb® TKQ

Supported balcony - outside wall with thermal insulation composite system

In this installation, the insulation panel of the Thermokorb®TKQ is outside the masonry wall and connects to the thermal insulation composite system.

Supported balcony - outside wall with thermal insulation composite system

Supported balcony with precast slab elements on the inside – outside wall without thermal insulation composite system

Thermokorb®TKQ is arranged within the masonry wall and the slab consisting of precast elements is used on the inside.

Supported balcony with precast slab elements on the inside – outside wall without thermal insulation composite system

Supported balcony with a downward level change

Thermokorb® TKQ at a supported balcony with a downward level change.

Supported balcony with a downward level change

Supported balcony with an upward level change

Thermokorb® TKQ at a supported balcony with an upward level change.

Supported balcony with an upward level change

Specification

TypeRib design - number of ribsRib height [cm]BCT** or Insulation height [cm]Fire proofing: R60 or REI120
TKQR1/2/31116/18/20/22/24R60/REI120
*R=element length depends on the number of ribs. **Building component thickness.

Type/Rib design Rib height/BCT or Insulation height (Note)

Example:

TKQ/R2 11/20 REI120

TKQ with two ribs, rib height 11cm, BCT 20, REI 120 required

Can’t find what you’re looking for?