Concrete balconies

TKM Thermokorb®

Our TKM Thermokorb® in collaboration with AVI sets the standard for thermal break solutions. With exceptional load-bearing capabilities, our product provides a superior level of thermal insulation between building elements, contributing to the construction of low-energy buildings. TKM Thermokorb® can be used for concrete-to-concrete balconies, connecting unsupported cantilever balcony slabs as well as special solutions, e.g. for level changes, cantilever slab connections to walls and wall connections.

Contact us
Balcony connector TKM styled image
Balcony connector TKM real image
1 of 2

Applications and features

Applications:

  • Concrete-to-concrete balconies.
  • Unsupported cantilever balcony slabs.
  • Continuous slabs (indirect support).
  • Special solutions are possible, e.g. for level changes, cantilever slab connections to walls, wall connections.

Features:

  • Fire resistance class REI 120.
    Also available in fire resistance class REI 120.
  • Detailed planning literature.
    Technical Information, Certificates, Approvals and Installation instructions.
  • Standardised.
    Available in standard heights of 160mm – 250mm; other heights and constructions available on request.
  • Best possible thermal insulation.
    80 mm - 120 mm insulation thickness and compression module.

Product variants

TKM/G

Straight (also for applied forces with changing signs).

TKM/E

Bent up (e.g. for precast concrete floor slabs).

TKM G ri
TKM E ribs

TKM/G-SF1

Step down balconies

TKM/G-SF

Step up balconies


Installation cases with TKM standard ribs

Cantilever balcony slab – External wall with composite heat insulation system

The insulating body of the Thermokorb is located outside of the wall in this installation example and connects with the composite heat insulation system.

The insulating body of the Thermokorb is located outside of the wall in this installation example and connects with the composite heat insulation system.

Cantilever balcony slab – External wall without composite heat insulation system

The insulating body of the Thermokorb is located within the wall. In this installation example, a precast concrete floor slab is set on the inside. The lower stirrup leg of the TKM/E rib is bent up to avoid a collision with the precast slab element.

Cantilever balcony slab – External wall without composite heat insulation system.

Installation cases with TKM special ribs

Balcony with step-up level change

The insulating body of the Thermokorb is located outside of the wall in this installation example and connects with the composite heat insulation system.

Balcony with step-down down level change

The insulating body of the Thermokorb is located outside of the wall in this installation example and connects with the composite heat insulation system.


Specification

TypeRib executionNumber of ribsExecutionRib heightInsulation heightNote
TKM–/Rmaximum 10G/E/SF110/130/ 150/170/190≥ 160/180/ 200/220/240REI120

Type/Rn(G or E or SF) RH/D (Note)

Examples:

  • TKM/6G 150/200 REI120
    TKM with 1000 wide, 6 G-type ribs, 150 mm rib height, 200 mm insulation height and 120-minute fire protection